Diffraction Gratings

A range of gratings are available depending on the spectral range of consideration. Diffraction gratings are supplied in pairs, on kinematic mounts to permit easy installation in the DMc150 without compromising the wavelength calibration.

Grating

Line density (g/mm)

Grating type & Blaze wavelength

Maximum wavelength range (nm)

GA-G1524H0U25

2400

Plane holographic, 250nm blaze

200-600

GA-G1518H0U25

1800

Plane holographic, 250nm blaze

200-800

GA-G1518R0U5

1800

Plane ruled, 500nm blaze

200-800

GA-G1512R0U4

1200

Plane ruled, 400nm blaze

300-1,100

GA-G1512R0U5

1200

Plane ruled, 500nm blaze

300-1,100

GA-G1512R0U75

1200

Plane ruled, 750nm blaze

450-1,100

GA-G15083R1U2

830

Plane ruled, 1.2µm blaze

650-1,700

GA-G1506R1U25

600

Plane ruled, 1.25µm blaze

800-2,400

GA-G1506R1U6

600

Plane ruled, 1.6µm blaze

800-2,400

Order Sorting

A filter wheel is located behind the entrance slit of the DMc150 to accommodate a shutter and long pass filters as required for the spectral range of operation. A six position filter wheel, for 25mm diameter filters is fitted as standard. An eight position filter wheel, for 22mm diameter filters is required where more positions are required.

Spectral range

Required OS filter

<400 nm

Under standard conditions- none required

Under purged operation

OS310

400-700nm

OS400

700-1250nm

OS700

1250-2000nm

OS1250

2000-3600nm

OS2000

Slit Configuration

The DMc150 can be configured in the compact, in-line or dual layouts. In the latter case a solenoid-driven programmable swing away mirrors (SAM), controlled by the internal drive electronics, is fitted for port selection.

Slit Type

The dimension of the largest of the entrance/ exit slits defines the bandwidth of the monochromator. Fixed, micrometer variable and motorised variable slits are offered, with a slit height of 20mm. For tuneable light source applications a range of exit slit apertures are available. Please enquire for further information.

Slit type

Features

Fixed slits (FSS)

- Manually controlled

- Spring leaf to ensure the correct placement of the slit

Micrometer variable slits (VSS)

- Manually controlled

- Bi-lateral slits

- Variable from 10µm to 10mm

Motorised variable slits (MVSS)

- PC control via USB

- Driven via internal monochromator electronics or external MAC electronics bin

- Comprising stepping motor driven bi-lateral slits

- Variable from 10µm to 10mm

Further Options

Neutral density filters

A range of metallic neutral density filters, for installation in the IDR150 filter wheel, are available for the purposes of signal attenuation.

Purge port

Installation of purge ports on IDR150 to enable purging of the space within the monochromator for VUV work.

Share this:

The Bentham Standard

We’re with you from the first call to the final result

Call us on +44 118 975 1355 or email us