BPC300 Photochromic Lens Spectrophotometer

  • BPC300 Photochromic Testing System
  • BPC300 Photochromic Testing System
  • Transmission Measurement of Photochromic Lens
  • BPC300 Optical Probe
  • BenWin+ Software Screenshot

The fully automated BPC300 enables product testing of prescription and non-prescription sunglasses in accordance with international standards, and the development of photochromic formulations.

The versatile BPC300 permits darkening and fading-back kinetic studies, whilst the modification of sample temperature, conditioning beam illuminance and spectrum accounts for a broad range of lens exposure conditions. An optional polarising lens capability is on offer for the extension of the measurement scope.

Core benefits

Features

  • Monochromator based, collimated tuneable light source (280-780nm)
  • Temperature-controlled water bath with mount for plano lens sample
  • AM2 conditioning beam (including facility to attenuate and filter spectrum)
  • Optically chopped monochromatic beam with lock-in signal recovery enables measurement under AM2 activation
  • Automated reference level measurement
  • Fully-automated by Windows application including establishment and running of pre-defined measurement profiles
  • Generation of measurement report including parameters required by standards

Applications

  • ISO/ EN 8980-3:2013 - "Ophthalmic optics. Uncut finished spectacle lenses. Transmittance specifications and test methods."
  • ISO/ EN 12312-1:2013 - "Eye and face protection. Sunglasses and related eyewear. Sunglasses for general use."
  • ANSI Z80.3: 2015 - "Non-prescription Sunglass and Fashion Eyewear Requirements."
  • A S/NZS 1067-2016 - "Sunglasses and fashion spectacles."

Reported Parameters

  • τV0 : Luminous transmittance in the faded state at (25±2)°C
  • τV1 : Luminous transmittance in the darkened state at (25±2)°C
  • τV0 /τV1 : Photochromic Response
  • Lens category
  • Colourimetric parameters: CIE 1931 & CIE Lab
  • τSUVA : Mean UVA spectral transmittance weighted by AM2
  • τSUVB : Mean UVB spectral transmittance weighted by AM2
  • Qsign : Visual attenuation coefficient for red, green, blue and yellow incandescent
  • τsb : Solar blue light transmittance
  • The rate of darkening and fading at a single wavelength

Optional reports include:

  • τVW : Luminous transmittance at (5±2)°C
  • τVS : Luminous transmittance at high temperature (35±2)°C
  • τVA : Luminous transmittance at reduced solar simulator level and (25±2)°C

Measurement

Spectral range of operation

280-780nm

Bandwidth

5nm

Wavelength accuracy

± 0.1nm (2400g/mm), ± 0.2nm (1200g/mm)

Beam diameter at sample plane

4mm diameter

Measured transmission range

0.5-100%

Maximum sample diameter

75mm

Conditioning beam

AM2 with requirements of ISO8980-3:2013

0-50klx

Shutter

Optional filtering

Temperature range

20-50°C

Temperature accuracy

± 0.2°C

Bench space required

1m deep x 2.5m wide

Services requirements

6 x main sockets 1200W power consumption

Nitrogen gas supply where measurements below ambient are required

Monochromatic Probe Source

UV source

30W Deuterium lamp

 

UV-Vis source

100W Quartz Halogen lamp

 

Monochromator configuration

Symmetric, single Czerny-Turner

 

Monochromator focal length

300mm

 

Diffraction gratings

2400 & 1200 g/mm

 

Diffraction grating mount

Triple grating turret

 

Dispersion

5.4nm/mm (2400g/mm)

2.7nm/mm

(1200g/mm)

Bandwidth

5nm

 

Wavelength accuracy

± 0.1nm (2400g/mm)

± 0.2nm (1200g/mm)

 

Chopping frequency

175 Hz (typical)

 

Beam diameter at sample plan

4mm diameter

 

Water Bath

Temperature range

20-50°C

Temperature accuracy

±0.2°C

Conditioning Beam

Spectral match

AM2 with requirements of ISO8980-3:2013

Beam illuminance

0-50klx

Beam filtering

Optional filtering

Computer requirements

OS

Windows 7, Windows 8 (32-/64-bit) operating systems (or newer)

Software control

BenWin+ Spectral acquisition software

Minimum hard disk space

Approx. 100MB

Minimum RAM

2 GB

Interface

4 x USB 2.0 ports

Options

BPC300

Photochromic lens spectrophotometer

BPC300_POLARISE

Polarised lens testing add-on to BPC300

Ordering information

BPC300

Photochromic lens spectrophotometer

BPC300_POLARISE

Polarised lens testing add-on to BPC300

09101

Replacement 100W QTH Lamp

27441

Replacement 30W Deuterium lamp

19084

Replacement 150W Xenon Lamp

Share this: