Set around a tuneable monochromatic light source, the PCS300 enables the spectral responsivity measurement of photometers to determine their deviation from the desired CIE V(λ) function, represented by the f1’ mismatch index. Furthermore, product development is empowered by the possibility of measuring the component detectors and filters of photometers, ensuring blocking out of band. The addition of a motorised goniometer allows the measurement of directional response.

Easy to use, the PCS300 will directly report the values important to demonstrate the performance of your photometers. Compliment the PCS300 with the LuxCal250 for the calibration of lux and luminance meters according to ISO/CIE 19476:2014.

Core benefits

Features

  • Xenon lamp/ single monochromator tuneable light source
  • Dual optical path optic to couple light to DUT and reference photodiode for parallel measurement (luxmeters)
  • Integrating sphere accessory for characterisation of luminance meter spectral mismatch
  • Collimated deuterium/ halogen source option for measurement of filter transmission
  • Motorised single axis goniometer with manual DUT 90° rotation for directional response measurement
  • Fully automated using Benwin+ spectral acquisition application
  • Calibration traceable to Physicalish Technische Bundesanstalt (PTB, Germany)

Applications

  • ISO/CIE 19476:2014, Characterization of the performance of illuminance meters and luminance meters

 Reported Parameters

  • General V(λ) mismatch index, f1
  • Directional response index, f2
  • filter transmission (%)
  • detector responsivity (A.W-1)

Tuneable Light Source

Probe light source

150W xenon

Monochromator configuration

Triple grating, symmetric, single Czerny-Turner, 300mm focal length

Bandwidth

Adjustable fixed slit, 1-10nm typical

Wavelength range

2400 g/mm grating: 250-320nm

1800 g/mm grating: 320-800nm

1200 g/mm grating: 800-1100nm

Resolution

250-320nm: 0.15nm

320-800nm: 0.2nm

800-1100nm: 0.3nm

Dispersion

250-320nm: 1.35nm/mm

320-800nm: 1.8nm/mm

800-1100nm: 2.7nm/mm

Wavelength accuracy

250-320nm: ± 0.1nm

20-800nm: ± 0.15nm

800-1100nm: ± 0.2nm

Picoammeter

Channel 1 input

Current input to picoammeter

Channel 2 input

Current input to picoammeter

Gain ranges

1010-105 V/A

Maximum current Input

100µA

Frequency response

DC

Gain accuracy

+1%

Gain stability

200ppm/°C

Output stability

5ppm/°C to 500ppm/°C depending on sensitivity

Linearity

< 0.025% departure from linearity from zero to full scale

ADC resolution

4½ digit BCD (0 to 19999) i.e. > 14 bit resolution

ADC integration time

100ms

Picoammeter input impedance

Virtual earth

PCS300_0001 luxmeter measurement accessory

Probe beam

Size 3x3mm

Beam splitter

Synthetic fused silica window

Reference photodiode

Si-CAL spectral responsivity standard

Calibration type and range

Short-circuit spectral responsivity, 360-830nm

Calibration traceability

Physicalish Technische Bundesanstalt (PTB, Germany)

DUT mount

Custom mount. Please use our online form to enquire.

Software report

Spectral responsivity, f1

PCS300_0002 luminance meter measurement accessory

Sphere diameter

100mm

Sphere exit port diameter

10mm

Sphere coating

BaSO4

Calibration type and range

Short-circuit spectral responsivity, 360-830nm

Calibration traceability

Physicalish Technische Bundesanstalt (PTB, Germany)

Software report

Spectral responsivity, f1

PCS300_0003 directional response accessory

Source

CL6-H enclosed 150W Halogen lamp

Typical lamp distance

2m

DUT mount

Custom mount. Please use our online form to enquire.

DUT rotation

One axis motorised, manual rotation of mount through 90°

Angular accuracy

≤0.1°

Angular resolution

≤0.001°

Software report

Directional responsivity, f2

PCS300_0004 filter transmission accessory

Illumination type

Polychromatic, collimated beam

Light source

ILD-D2-QH deuterium-halogen source

Collimator

COL_2_UV-VIS collimator

Detectors

DH_30 multi-alkali photomultiplier & DH_Si silicon photodiode

Sample holder

Custom sample holder up to 15mm diameter. Please use our online form to enquire.

Options

PCS300_0001

General V(λ) mismatch index of luxmeters, f1

PCS300_0002

General V(λ) mismatch index of luminance meters, f1

PCS300_0003

Directional response index, f2

PCS300_0004

Filter transmission (%)

Ordering Information

PCS300_0001

General V(λ) mismatch index of luxmeters, f1

PCS300_0002

General V(λ) mismatch index of luminance meters, f1

PCS300_0003

Directional response index, f2

PCS300_0004

Filter transmission (%)

Software

The PCS300 may be controlled over the USB 2.0 interface using our Windows application Benwin+ or by user written code based on our SDK on a wide range of platforms (Labview, Matlab, C++ etc.) Using configuration files, both applications allow: 

  • Accessing grating filter wheel and slit properties
  • Wavelength selection
  • Spectral measurements

Benwin+ includes higher functionality including:

  • Easy system calibration
  • Obtain spectrally integrated (and weighted) quantities
  • Instantly obtain colorimetric data
  • Perform transmission, absorption and reflection measurements
  • Perform simple arithmetic functions
  • Utilities for control of translation stages, goniometers, RSB, data acquisition from other instruments etc.

Share this:

The Bentham Standard

We’re with you from the first call to the final result

Call us on +44 118 975 1355 or email us