TMS300 Single Monochromator

  • TMS300 Single Monochromator

Within the TMS300, up to three gratings are mounted on a turret which can be rotated through 360° allowing software selection of grating type and position. A selection of large rectangular gratings enhances light throughput whilst optical layout minimises the impact of scattered light.

Core benefits

Features

  • 300mm focal length single monochromator in Czerny-Turner configuration
  • Configured over ranges 200nm-50µm and below 300nm
  • Accommodates up to three diffraction gratings to permitting single–scan measurement over broad spectral range
  • Up to two entrance and/or exit ports with automated mirror-based port selection for use of multiple input/ output/ detector configurations
  • Internal motorised entrance and exit slits
  • Also available as a double monochromator with additive dispersion

Optical Layout

ConfigurationSymmetrical Czerny Turner
Focal length300mm
Grating mountTriple grating turret
Number of gratings1-3
Grating size68 x 84mm
Aperture ratiof/4.1 (at all grating angles)
Number of entrance/ exit ports1/2 or 2/1

Opto-Mechanical

Mechanical resolution drive0.00072°/ step
Slit typeInternal motorised variable
Slit width & height10µm-10mm (W) x 20 (H)
Filter size6-position filter wheel
Filter diameter25mm (see separate Order Sorting Filter datasheet for full range)

Optical Performance (quoted for 1200 g/mm gratings)

Spectral rangeWithin range 200nm-50µm
Linear dispersion2.7nm/mm
Wavelength accuracy± 0.2nm
Wavelength reproducibility± 0.05nm
Resolution full/reduced slit height0.3/0.1nm
Stray light rejection at 2.5 FWHM10-5
Wavelength acquisition speed1000nm/s

Automation

Computer interfaceUSB 2.0
Software controlBenWin+/SDK

Electrical/ Mechanical

Overall dimensions328L x 375W x 263H mm
Optical height178mm
WeightApprox. 15kg
Power supplyMains input 110/220V 50/60Hz

Options

Diffraction gratingsSee Configurations Tab
Order sorting filtersSee Configurations Tab
Filter wheel252-6 (6-position filter wheel, includes shutter)

Diffraction Gratings

A range of gratings are available depending on the spectral range of consideration. A range of gratings are available depending on the spectral range of consideration, with up to three diffraction gratings mounted to the turret of the TMS300.

GratingLine density (g/mm)Grating type & Blaze wavelength Maximum wavelength range (nm)
GA-T324R0U252400Plane ruled, 250nm blaze200-600
GA-T324H0U252400Plane holographic, 250nm blaze200-600
GA-T324H0U32400Plane ruled, 300nm blaze200-600
GA-T318H0U251800Plane holographic, 250nm blaze250-900
GA-T318R0U41800Plane ruled, 400nm blaze250-900
GA-T318R0U51800Plane ruled, 500nm blaze250-900
GA-T312H0U251200Plane holographic, 250nm blaze300-1200
GA-T312R0U41200Plane ruled, 400nm blaze300-1200
GA-T312R0U51200Plane ruled, 500nm blaze300-1200
GA-T312R0U751200Plane ruled, 750nm blaze300-1200
GA-T312R0U91200Plane ruled, 900nm blaze300-1200
GA-T312R1U01200Plane ruled, 1µm blaze300-1200
GA-T3083R1U2830Plane ruled, 1µm blaze600-1800
GA-T306R1U0600Plane ruled, 1µm blaze800-2500
GA-T306R1U25600Plane ruled, 1.25µm blaze800-2500
GA-T306R1U6600Plane ruled, 1.6µm blaze800-2500
GA-T306R1U9600Plane ruled, 1.9µm blaze800-2500
GA-T306R2U16600Plane ruled, 2.16µm blaze800-2500
GA-T304R1U6400Plane ruled, 1.6µm blaze1000-3000
GA-T303R3U0300Plane ruled, 3µm blaze1500-5500
GA-T303R4U0300Plane ruled, 4µm blaze1500-5500
GA-T3015R4U0-AU150Plane ruled, 4µm blaze. Gold coated.300-10,000
GA-T3015R6U0-AU150Plane ruled, 6µm blaze. Gold coated.3000-10,000
GA-T301R9U0-AU100Plane ruled, 9µm blaze. Gold coated.4500-16,000
GA-T30075R10U0-AU75Plane ruled, 10µm blaze. Gold coated.6000- 2,000
GA-T30075R12U0-AU75Plane ruled, 12µm blaze. Gold coated.6000-22,000
GA-T3005R18U0-AU50Plane ruled, 18µm blaze. Gold coated.9000-30,000
GA-T3005R19U5-AU50Plane ruled, 19.5µm blaze. Gold coated.9000-30,000

Slits

Slit typeFeatures
Fixed slits (FSS)- Manually controlled
- Spring leaf to ensure the correct placement of the slit
Micrometer variable slits (VSS)- Manually controlled
- Bi-lateral slits
- Variable from 10µm to 10mm
Motorised variable slits (MVSS)- PC control via USB
- Driven via internal monochromator electronics or external MAC electronics bin
- Comprising stepping motor driven bi-lateral slits
- Variable from 10µm to 10mm

Filters

An order sorting filter wheel is located inside the entrance port of the monochromator, fitted with 6 filters selected for the spectral range of use.

When measuring below 400nm, no filters are required as the corresponding wavelength of the subsequent diffraction order is less than 200nm, which is naturally blocked by the atmosphere.

Spectral rangeRequired OS filter
<400 mNone
400-700nmOS400
700-1250nmOS700
1250-2000nmOS1250
2000-3600nmOS2000
3.6-6 µmOS3600
6-10.5 µmOS6000
10.5-21 µmOS10500
> 21µmPlease consult.

Further Options

ND/ BP filtersNeutral density filters, used to attenuate optical signal level or band pass filters, to improve monochromator stray light performance, may be mounted in the filter wheel.
Purge portsPurge ports fitted to monochromator to allow purging with nitrogen to remove atmospheric absorbants which absorb in the UV (<200nm) and IR (Various absorption bands).
Toroidal mirrorsToroidal mirrors spherical mirrors replaced with toroidal mirrors for imaging applications.
Turret-mirrorA mirror may be fitted on a free location on the turret for the purposes of relating un-diffracted light to the exit port.
418-INT418 optical chopper mounted behind the entrance slit.
Interchangeable turretsFor applications where very wide spectral range or regional optimisation is required, an interchangeable turret is available allowing the exchange of groups of three diffraction gratings to cover different spectral regions. In this case, the stepping motor in this case drives a platform to which is attached the grating assembly.
ShutterSolenoid-based shutter for timed exposure applications.

Monochromator Dimensions

TMs300 Dimensions - Side View
TMs300 Dimensions - Side View
TMs300 Dimensions - Top View
TMs300 Dimensions - Top View

Software Control

The TMS300 may be controlled by PC, facilitated via a USB 2.0 interface by Bentham’s Benwin+ spectroradiometer software, responsible for:

  • Accessing grating filter wheel and slit properties
  • Identifying grating type and position
  • Wavelength selection and calibration
  • Spectral measurements
  • System calibration
  • Configuration files syntax

Alternatively, Bentham offers a comprehensive SDK for user-written programs, available across a wide range of platforms (LabVIEW, Matlab, C++, SPCI protocol, etc.).

The Bentham Standard

We’re with you from the first call to the final result

Call us on +44 118 975 1355 or email us