CL7 Deuterium Spectral Irradiance Standard (200-400nm)

  • CL7 Deuterium Irradiance Calibrator
Call us:
+44 118 975 1355
Email Us

Calibrated in our dedicated laboratory with respect to standards calibrated by the Physicalish Technische Bundesanstalt (PTB, Germany), calibration is provided over the range 200-400nm.

Fitted with a high performance 30W deuterium lamp, the entrance optic of the spectroradiometer is simply 'plugged in' to a highly-reproducible position using an interchangeable adaptor. A range of such interchangeable adapters accommodate Bentham's range of transmission diffuser and integrating sphere entrance optics.

Stable lamp operation may be ensured in operating the CL7 with the 706 deuterium lamp supply.

Core benefits

Features

  • Enclosed deuterium  spectral irradiance standard lamp (mW-1.m-2.nm-1)
  • Spectral irradiance calibration range 200-400nm
  • High performance 30W deuterium lamp
  • Calibration distance set by entrance optic adapter
  • Designed for optimal performance when powered by the 706 deuterium lamp power supply
  • Calibration performed with respect to Physicalish Technische Bundesanstalt (PTB, Germany)

Electro-Optical

Lamp typeDeuterium lamp
Nominal lamp power and voltage30W, 100 V
Operating current300mA DC
Expected lifetime2000h
Peak spectral irradiance (typ.)8 mW.m-2.nm-1 at 200nm
UV-A (315-400nm) irradiance (typ.)53 mW.m-2
UV-B (280-315nm) irradiance (typ.)49 mW.m-2
UV-C (200-280nm) irradiance (typ.)327 mW.m-2

Calibration

Measurement typeSpectral irradiance at 5.5mm from plane of front face
Wavelength range200-400nm
Wavelength interval2nm
TraceabilityPhysicalish Technische Bundesanstalt (PTB, Germany)
Calibration frequencyRecommended after 100 hours burn-time

Mechanical

Connector4mm socket
Dimensions91.2L x 44.4W x 76.2H (mm)

Entrance Optic Adapters (DAR series)

DIFF_D6_DARAdapter for D6 & D7 transmission diffusers
DIFF_D6_H_DARAdapter for D6_H & D7_H transmission diffusers
DIFF_D7_QD_DARAdapter for D7_QD environmentally sealed transmission diffusers
DIFF_D8_DARAdapter for D8 integrating sphere
DIFF_DAR_IS75Adapter for IS75 environmentally sealed integrating sphere

Calibration

DIFF_D6_DARAdapter for D7 transmission diffuser
DIFF_D6_H_DARAdapter for D7_H transmission diffuser
CALIBRATION-CL7-HCL7 spectral irradiance calibration 200-400nm
CL7 Dimensions Calibration Standard - Front View
CL7 Dimensions - Front View
CL7 Dimensions Calibration Standards - Side View
CL7 Dimensions - Side View
CL7 Dimensions Calibration Standards - Top View
CL7 Dimensions - Top View
Typical CL7 Measurement Data Graph
Typical Irradiance of CL7

Ordering Information

CL7_HDeuterium spectral irradiance standard
DIFF_D6_DARAdapter for D6 & D7 transmission diffusers
DIFF_D6_H_DARAdapter for D6_H & D7_H transmission diffusers
DIFF_D7_QD_DARAdapter for D7_QD environmentally sealed transmission diffusers
DIFF_D8_DARAdapter for D8 integrating sphere
DIFF_DAR_IS75Adapter for IS75 environmentally sealed integrating sphere
CALIBRATION-CL7-HCL7 Spectral irradiance calibration 200-400nm