CL6 Halogen Spectral Irradiance Standard (250-3000nm)

  • CL6-H QTH spectral irradiance reference standard
  • CL6-H QTH spectral irradiance reference standard 250-3000nm

Calibrated in our dedicated laboratory with respect to standards calibrated by the Physicalish Technische Bundesanstalt (PTB, Germany), Bentham offers a range of calibration intervals within 250-2500nm, with a De Vos extrapolation of calibration data provided to 3000nm.

Fitted with a grit-blasted 150W QTH lamp, the CL6 is offered in two configurations, with horizontal and vertical mount. In both cases, the entrance optic is simply 'plugged in' to a highly-reproducible position.

Stable lamp operation may be ensured in running the lamp with the 610 precision constant current DC power supply.

Core benefits

Features

  • Enclosed quartz tungsten halogen spectral irradiance standard lamp
  • Spectral irradiance calibration range 250-2500nm with De Vos extrapolation to 3000nm
  • Range of reliable QTH lamps available
  • Calibration distance set by entrance optic adapter
  • Designed for optimal performance when employed with the 610 current stabilised lamp power supply
  • Calibration performed with respect to Physicalish Technische Bundesanstalt (PTB, Germany)

Electro-Optical

Lamp type

Grit-blasted quartz tungsten halogen lamp, G6.35 base

Nominal lamp power and voltage

150W, 24V

Operating current

6.3A

Expected lifetime

2000 hours

Spectral irradiance at peak (typ.)

140 (mW/m2.nm) at 770nm

Illuminance (typ.)

(6300 Lux)

Correlated colour temperature (typ.)

3360 K

Chromaticity coordinates, CIE 1931 & 1976

x = 0.414, y = 0.396, u' = 0.239, v' = 0.515

Calibration

Measurement type

Spectral irradiance at 5.5mm from front face of CL6

Wavelength range

300nm-800nm

Wavelength interval

5nm

Calibration frequency

Recommended after 100 hours burn-time

Traceability

Physicalish Technische Bundesanstalt (PTB, Germany)

Mechanical

Connector

4mm socket

Dimensions

290L x 125W x 110H (mm)

Mount

CAL_CL6-H

Horizontal mount for general purpose spectroradiometer calibration. Requires entrance optic adapter (see below)

CAL_CL6-V

Vertical mount to adapt to solar irradiance entrance optics installed outdoors

Entrance Optic Adapters (DAR series)

DIFF_D6_DAR

Adapter for D7 transmission diffuser

DIFF_D6_H_DAR

Adapter for D7_H transmission diffuser

DIFF_D7_QD_DAR

Adapter for D7_QD environmentally sealed transmission diffusers

DIFF_D8_DAR

Adapter for D8 integrating sphere

DIFF_DAR_IS75

Adapter for IS75 environmentally sealed integrating sphere

Calibrations

CALIBRATION-CL6-H

CL6-H Spectral irradiance calibration 300-800nm. De Vos extrapolation to 3000nm

CALIBRATION-CL6-H-D8

CL6-H Spectral irradiance calibration 300-800nm for use with D8 integrating sphere. De Vos extrapolation to 3000nm

CALIBRATION-CL6-H-UV

CL6-H Spectral irradiance calibration 300-800nm for use with D8 integrating sphere. De Vos extrapolation to 3000nm

Ordering Information

CAL_CL6-H

Horizontal mount for general purpose spectroradiometer calibration. Requires entrance optic adapter (see below)

CAL_CL6-V

Vertical mount to adapt to solar irradiance entrance optics installed outdoors

DIFF_D6_DAR

Adapter for D6 & D7 transmission diffusers

DIFF_D6_H_DAR

Adapter for D6_H & D7_H transmission diffusers

DIFF_D7_QD_DAR

Adapter for D7_QD environmentally sealed transmission diffusers

DIFF_D8_DAR

Adapter for D8 integrating sphere

DIFF_DAR_IS75

Adapter for IS75 environmentally sealed integrating sphere

CALIBRATION-CL6-H

CL6-H Spectral irradiance calibration 300-800nm. De Vos extrapolation to 3000nm

CALIBRATION-CL6-H-D8

CL6-H Spectral irradiance calibration 300-800nm for use with D8 integrating sphere. De Vos extrapolation to 3000nm

CALIBRATION-CL6-H-UV

CL6-H Spectral irradiance calibration 300-800nm for use with D8 integrating sphere. De Vos extrapolation to 3000nm

PSU_610

Current stabilised lamp power supply

Share this: