CL3 Deuterium Spectral Irradiance Standard (200-400nm)

  • CL3 calibration spectral irradiance reference standard side dimensions

Calibrated in our dedicated laboratory with respect to standards calibrated by the Physicalish Technische Bundesanstalt (PTB, Germany), calibration is provided over the range 200-400nm.

The CL3 houses a high performance 30W deuterium lamp matched to the 706 deuterium lamp supply.

Optical bench compatible mounting holes in the base of the CL3 facilitate positioning, whilst the calibration distance is set at a distance of 200mm using a spacer bar. The CL3 may be used alongside an optional BenFlect diffuse reflectance tile and mount to constitute a traceable UV spectral radiance standard.

Core benefits

Features

  • Open-frame spectral irradiance calibration standard (mW-1.m-2.nm-1)
  • Spectral irradiance calibration range 200-400nm
  • Calibration distance measured from a simple datum face
  • Designed for optimal performance when powered by the 706 deuterium lamp power supply
  • Calibration performed with respect to the Physicalish Technische Bundesanstalt (PTB, Germany)
  • Optional diffuse reflectance tile and mount available

Electro-Optical

Lamp type Deuterium lamp
Nominal lamp power and voltage 30W, 100 V
Operating current 300mA DC
Expected lifetime 2000h
Peak spectral irradiance (typ.) 4 mW.m-2.nm-1 at 200nm
UV-A (315-400nm) Irradiance (typ.) 40 mW.m-2
UV-B (280-315nm) Irradiance (typ.) 35 mW.m-2
UV-C (200-280nm) Irradiance (typ.) 205 mW.m-2

Calibration

Measurement type Spectral irradiance at 200mm from front face
Wavelength range 200-400nm
Wavelength interval 2nm
Traceability Physicalish Technische Bundesanstalt (PTB, Germany)
Calibration frequency Recommended after 100 hours burn-time

Mechanical

Connector 4mm socket
Dimensions 64L x 64W x 206H (mm)

Calibration

CALIBRATION-CL3 CL3 Spectral irradiance calibration 200-400nm

Options

CL3_RADIANCE_ACCESSORY Diffuse reflectance tile and mount for CL3 to provide spectral radiance standard 200-400nm
CL3 spectral irradiance reference standard side profile
CL3 calibration standard dimensions

Ordering Information

CL3 Deuterium spectral irradiance standard
CL3_RADIANCE_ACCESSORY Diffuse reflectance tile and mount for CL3 to provide spectral radiance standard 200-400nm
CALIBRATION-CL3 CL3 Spectral irradiance calibration 200-400nm