Abstract

A goniofluorometer has been built that is capable of measuring in various viewing angles ranging from 10° to 90°. The incident angle can be varied from 0° to 8°. The goniofluorometer can measure bispectral luminescent radiance factors in the wavelength range of 250–800 nm.

To our knowledge, there are no other reported results of similar devices capable of spectral measurements in various measurement geometries.

© 2008 Optical Society of America

Citation

Holopainen, S., Manoocheri, F. and Ikonen, E., 2008. Goniofluorometer for characterization of fluorescent materials. Applied optics, 47(6), pp.835-842.